
At Advanced Environmental Services (AES), we specialize in PFAS sampling and testing methods designed to accurately detect and measure per- and polyfluoroalkyl substances (PFAS) in soil, groundwater, and drinking water. Serving clients across Missouri and the Midwest, AES combines advanced field techniques, accredited laboratory analysis, and decades of environmental experience to deliver dependable results that guide informed decision-making and regulatory compliance.
PFAS compounds are highly persistent and mobile in the environment, making proper sampling and testing essential for any site investigation or remediation plan. With precision, consistency, and attention to detail, AES provides the expertise you can trust to accurately characterize contamination and protect public health.
To learn more about PFAS testing and analysis services or request a consultation with our team, contact us online or by phone today.
Comprehensive PFAS Sampling and Testing Services
AES offers complete PFAS sampling and testing solutions tailored to the needs of municipalities, industrial clients, and property owners. Every step of our process is designed to maintain sample integrity and meet the most stringent quality assurance standards.
PFAS Sampling Services
Our trained field technicians collect samples from soil, groundwater, surface water, and drinking water using specialized non-fluorinated equipment to eliminate cross-contamination. We follow strict sampling protocols based on EPA and state guidelines, including:
- EPA Method 537.1 and 533 for drinking water analysis
- EPA Draft Method 1633 for wastewater, soil, and groundwater sampling
AES technicians are trained to recognize and avoid PFAS-containing materials during sampling, from gloves and sample bottles to clothing and field gear, ensuring every sample collected reflects true environmental conditions.
Laboratory Testing and Analysis
All PFAS samples collected by AES are analyzed through certified laboratories equipped with high-resolution mass spectrometry (LC-MS/MS) technology capable of detecting PFAS at parts-per-trillion (ppt) concentrations. Laboratory results identify both legacy compounds like PFOA and PFOS and newer replacement PFAS compounds.
Our laboratories maintain strict quality control standards, including method blanks, field duplicates, and calibration verification. Results are compiled into comprehensive reports that compare findings with federal and state advisory levels.
Data Interpretation and Reporting
Once the laboratory results are complete, AES environmental scientists analyze and interpret the data in context. We clearly outline the type and concentration of PFAS compounds detected and assess potential environmental and health risks. This data serves as the foundation for next steps, such as remediation design, ongoing monitoring, or regulatory reporting.
Techniques and Equipment Used for PFAS Sampling
AES uses specialized techniques and non-reactive materials designed to minimize sample contamination and ensure accuracy. Common tools and practices include:
- Dedicated sampling kits made from stainless steel, polypropylene, or HDPE (never Teflon or PTFE)
- Pre-cleaned containers and field blanks for quality assurance
- Low-flow groundwater sampling to reduce turbidity and prevent sample alteration
- Surface water and sediment sampling for runoff and discharge analysis
- Air and wipe sampling (when applicable) to assess potential PFAS transfer or airborne exposure
Our team stays current with evolving sampling technologies and EPA-approved methodologies, allowing us to deliver consistent, defensible results across all site conditions.
Why Choose Advanced Environmental Services
When accuracy, compliance, and reliability are critical, AES is the partner you can depend on for PFAS sampling and testing. Here’s what sets us apart:
Proven Experience
AES has decades of experience conducting environmental sampling and analysis throughout Missouri and the Midwest. Our deep understanding of regional geology and water systems helps us design effective, site-specific testing programs.
Certified Procedures and Laboratories
We work exclusively with certified laboratories and follow all EPA and ASTM protocols to ensure data validity. Every project includes strict documentation and chain-of-custody procedures.
Comprehensive, Turnkey Solutions
From site assessments and sampling to testing and remediation, AES provides a seamless approach to managing PFAS contamination, saving clients time and ensuring accountability.
Commitment to Compliance and Safety
Our team is committed to protecting both public health and environmental integrity. We help clients stay ahead of evolving PFAS regulations while minimizing project risks.
Frequently Asked Questions About PFAS Sampling
Why is PFAS sampling so complex?
PFAS compounds are found in many everyday materials, making contamination easy to introduce accidentally. Specialized equipment and procedures are needed to ensure accurate results.
How deep are samples collected during testing?
The depth depends on site conditions and potential PFAS sources. Samples are typically taken from multiple soil layers or groundwater wells to determine contamination spread.
How long does testing take?
Lab analysis generally takes two to four weeks, depending on the number of samples and the scope of the project.
Can AES handle both testing and remediation?
Yes. AES provides complete PFAS testing and management services, including site assessments, testing, removal, and long-term remediation.
Contact Advanced Environmental Services
Accurate PFAS sampling and testing are the foundation of every successful remediation plan. Trust the experienced professionals at AES to deliver reliable data and proven results.
Contact our environmental remediation company today at (314) 865-2662 or reach out online to schedule PFAS sampling or learn more about our testing and analysis services.



